• Chủ nhật, 24/10/2021
  • (GMT+7)
Nghiên cứu giá trị của chụp cắt lớp vi tính 128 định lượng trên bệnh nhân bệnh phổi tắc nghẽn mạn tính trước và sau ghép tế bào gốc tự thân

Nghiên cứu giá trị của chụp cắt lớp vi tính 128 định lượng trên bệnh nhân bệnh phổi tắc nghẽn mạn tính trước và sau ghép tế bào gốc tự thân

06/05/2021 15:35:43 | 0 binh luận

SUMMARY Background: Quantitative Computed Tomography (QCT) has been used for many years worldwide to evaluate and quantify lung parenchymal lesions in chronic obstructive pulmonary disease (COPD), including emphysema quantification (LAA-950), air-trapping assessment area (LAA- 856), bronchial wall area (WA), percentage of wall area (% WA), bronchial lumen area (LA), bronchial wall thickness (WT), studies show that QCT is highly accurate, strongly correlated with the respiratory function test (FEV1, FVC), grade classification according to GOLD. We applied this method to evaluate the indicators of emphysema (LAA-950), air-trapping (LAA-856), RVC¬856-950, bronchial wall area (WA), bronchial lumen (LA) and bronchial wall thickness (WT), percentage pulmonary vascular (%HAV) of COPD patients before and after autologous stem cell transplant from adipose tissue and bone marrow. Method: The study was conducted from 10.2019 - 10.2020 on 32 COPD patients diagnosed with COPD according to GOLD 2018 standards, patients with FEV1 <60% were selected for the autologous stem cell transplant study at The Respiratory Center - Bach Mai Hospital (4 GOLD II patients, 17 GOLD III patients, 11 GOLD IV patients). The patient was given quantitative CT scans 2 times, the first time before transplant and the second after 6 months after transplantation with a 128-detectors scanner of Siemens (Somatom Definition Egde) at Dien Quang Center - Bach Mai Hospital. Results: Percentage of emphysema (LAA-950) before grafting 31.49% ± 8.19, after grafting 32.8% ± 7.13), percentage of air-trapping in then exhalation (LAA-856) before grafting 63.65% ± 8.74, after transplant 61.41% ± 7.4 (statistically significant difference p = 0.026), RVC856- 950 before transplant 0.83 ± 1.82, post transplant 3.58 ± 1.76 (significant difference p = 0.000), these indicators are linearly correlated with FEV1, BODE and GOLD classification. The percentage of wall area (%WA) after transplantation was changed in the bronchial branch of segment 1 (70.74% before transplantation, 67.59% after transplantation, p = 0.02) and in branch of subsegment 1 (79.19% before transplantation, after transplantation 75.90%, p = 0.01), lumen area (LA), inner diameter (ID) of the posttransplant bronchial all increased in the segmental and subsegmental bronchial branches RB1, RB4, RB10, wall thickness (WT) decreased in the sub-branches RB1-1, RB4-1, RB10-1 (however the difference was not statistically significant with p <0.05). Conclusion: Emphysema (LAA-950), air-trapping (LAA-856, RVC856-950), percentage of bronchial wall (% WA), lumen area (LA), inner diameter (ID), thickness bronchial wall (WT) measured on QCT correlated with FEV1, FVC, GOLD, BODE before and after stem cell transplantation, can be used to assess the extent and stage of Chronic Obstructive Pulmonary Disease, pre- and post-assessment of autologous stem cell transplant therapy. Keywords: Quantitative CT COPD, Quantitative CT after autologous stem cell tranplantation
Cộng hưởng từ khuếch tán: Ứng dụng lâm sàng

Cộng hưởng từ khuếch tán: Ứng dụng lâm sàng

24/12/2019 18:00:25 | 0 binh luận

Ứng dụng chính của Cộng hưởng từ khuếch tán - DWI MR đã được dùng là hình ảnh não vì chủ yếu là độ nhạy tinh tế với đột quỵ thiếu máu-một bệnh lý thường gặp xuất hiện trong chẩn đoán phân biệt ở tất cả các bệnh nhân có triệu chứng thần kinh.
Chụp CT hai mức năng lượng: nguyên lý và ứng dụng lâm sàng

Chụp CT hai mức năng lượng: nguyên lý và ứng dụng lâm sàng

05/12/2019 09:51:32 | 0 binh luận

Dual energy computed tomography: basic principles and applications SUMMARY Computed tomography is a modern medical imaging with rapid development and many technical advances. Dual energy CT (DECT) is adevelopment that offers great promise to increase the CT potential. Conventional CT utilizes a single X ray beam and contrast image is generated by the differences in photon attenuation of materials. In DECT, two energy levels are used to acquire images.The tube potentials are mostly set to 140 and 80 kVp to obtain the largest spectral difference. DECT differsmaterial composition by different photon energy levels. DECT is widely indicated and some indications are routineclinical use. Clinical applications include, for example, the assessment of contrast enhancement in focal organ lesions, pulmonary perfusion, angiography with bone removal and display of plaque distribution, kidney stone differentiation, and detection of tophi... This article introduces some basic principles and clinical applications of DECT. Keywords: Dual energy CT, spectral, contrast image, attenuation, materials
Nghiên cứu hình ảnh cộng hưởng từ não của 5 trường hợp nhiễm độc chì mạn tính

Nghiên cứu hình ảnh cộng hưởng từ não của 5 trường hợp nhiễm độc chì mạn tính

02/04/2020 17:39:27 | 0 binh luận

Brain MRI findings in 5 cases of chronic lead toxicity SUMMARY: Lead is a heavy metal, it can be toxic to many organs in the body, among them are bone marrow, muscles, kidneys, endocrine glands, joints and nervous system. Encephalopathy is a rare but severe complication. In this report, we presented the brain MRI findings in 5 cases with blood lead level greater than normal and the clinical symptoms of lead poisoning. The results show, there are three types of images: (1) Edema and hyperintensive lesions on T2W and T2W FLAIR images in the insula and basal ganglia, symmetrical at both sides, caused by vascular injury. (2) Hyperintensive lesions on T1W images at the head of caudate nucleus and globus pallidus, considered to be due to metabolic disorder, which causes deposition of T1- intense elements there. (3) Normal brain MR images. MRI is a diagnostic imaging technique with high resolution, an useful mean for early detection of brain damage in patients with chronic lead poisoning.
Đánh giá tương quan giữa Ferritin huyết thanh và  tình trạng ứ sắt ở gan, lách và tim trên bệnh nhân  β-Thalassemia thể nặng bằng kỹ thuật cộng hưởng  từ T2*

Đánh giá tương quan giữa Ferritin huyết thanh và tình trạng ứ sắt ở gan, lách và tim trên bệnh nhân β-Thalassemia thể nặng bằng kỹ thuật cộng hưởng từ T2*

23/05/2020 11:28:15 | 0 binh luận

Evaluated the correlation between serum Ferritin and iron overload of liver, spleen and heart in β -Thalassaemia major patients by MRI T2* method
Hướng dẫn sử dụng các khám xét chẩn đoán hình ảnh

Hướng dẫn sử dụng các khám xét chẩn đoán hình ảnh

02/04/2020 14:37:59 | 0 binh luận

Tập tài liệu “Hướng dẫn sử dụng tốt các khám xét hình ảnh y khoa” ( Guide de bon usage des examens d’imagerie medicale ) được các tác giả ngành y tế Cộng hoà Pháp biên soạn và hiệu chỉnh trong suốt 4 năm từ 2001 đến 2004 và được xuất bản năm 2005 tại Pháp. Các tác giả tham gia biên soạn bao gồm nhiều nhóm chuyên gia của Hội Điện quang, Hội Lý sinh Y học và Y học hạt nhân Pháp cũng như các hội chuyên ngành lâm sàng và nhóm các nhà chức trách về quản lí y tế Pháp
Cộng hưởng từ tưới máu não nguyên lý và kỹ thuật

Cộng hưởng từ tưới máu não nguyên lý và kỹ thuật

17/04/2020 23:36:23 | 0 binh luận

Nội dung giới thiệu Các thông số tưới máu não Kĩ thuật Một số hình ảnh minh họa Kết luận
Nhận xét vai trò kỹ thuật viên trong chụp Xquang tuyến vú tại trung tâm điện quang bệnh viên Bạch Mai

Nhận xét vai trò kỹ thuật viên trong chụp Xquang tuyến vú tại trung tâm điện quang bệnh viên Bạch Mai

21/11/2019 09:21:59 | 0 binh luận

Nhóm nghiên cứu của Trung tâm Điện quang – Bệnh viện Bạch Mai đã triển khai đề tài “Nhận xét vai trò kĩ thuật viên trong chụp X Quang tuyến vú tại trung tâm điện Quang Bệnh viện Bạch Mai”. Đề tài được báo cáo tại Hội nghị Điện quang và Y học hạt nhân Việt Nam lần thứ 20 diễn ra tại Hà Nội
Box 1

VIDEO

box 2 Box 3 Box 4 Box 5 Triển lãm ASCI 2020 Triển lãm VSRNM 22

Đơn vị hợp tác