Gía trị của cắt lớp vi tính 64 dãy trong chẩn đoán u đầu tụy
The value of CT- Scanner 64 multi-detector in diagnosis of pancreatic head tumor
summary
Objectives: Evaluating the role of CT scanner 64 multidetector in diagnosing of pancreatic head tumor.
Subjects and methods: 57 patients were diagnosed of pancreatic head tumor on MSCT 64 multi-detector and were operated with pathology result confirmed from January 2012 to December 2012 in Viet Duc hospital.
Results: The sensitivity, specificity, fault negative rate, accurate diagnosis and positive predictive value of MSCT 64 detectors in definite diagnosis were 96%, 100%, 3.4%, 98%, and 100% respectively. The sensitivity, specificity, fault negative rate, accurate diagnosis and positive predictive value of MSCT 64 detectors in local invasive diagnosis were 74%, 87%, 26%, 86%, and 94% respectively. The evaluation vascular invasion were with the Se of 75%, Sp of 95%, FNR of 25%, ACC of 85%, PPV of 88%. The value of metastasis diagnosis were with Se of 57%, Sp of 85%, FNR of 43%, ACC of 71%, PPV of 72%. Accuracy of surgery technique proposing was 87.7%.
Conclusion: CT scanner 64 multi-detector has high sensitivity and specificity in definitive diagnosis, evaluating the invasion and proposing the diagnosis possibilities.
Key words: CT scanner 64 multi-detector, pancreatic head tumor.
Bạn Đọc Quan tâm
Sự kiện sắp diễn ra
Thông tin đào tạo
- Những cạm bẫy trong CĐHA vú và vai trò của trí tuệ nhân tạo
- Hội thảo trực tuyến "Cắt lớp vi tính đếm Photon: từ lý thuyết tới thực tiễn lâm sàng”
- CHƯƠNG TRÌNH ĐÀO TẠO LIÊN TỤC VỀ HÌNH ẢNH HỌC THẦN KINH: BÀI 3: U não trong trục
- Danh sách học viên đạt chứng chỉ CME khóa học "Cập nhật RSNA 2021: Công nghệ mới trong Kỷ nguyên mới"
- Danh sách học viên đạt chứng chỉ CME khóa học "Đánh giá chức năng thất phải trên siêu âm đánh dấu mô cơ tim"
Bình luận