NGHIÊN CỨU GIÁ TRỊ CỦA CHUỖI XUNG TƯỚI MÁU VÀ CHUỖI XUNG PHỔ TRÊN CỘNG HƯỞNG TỪ 3 TESLA CHẨN ĐOÁN PHÂN BẬC U THẦN KINH ĐỆM

SUMMARY

Purpose: To evaluate the diagnostic accuracy of magnetic resonance spectroscopy and dynamic contrast-enhanced (DCE) magnetic resonance perfusion for glioma grading.

Materials and Methods: Fifteen patient confirmed pathological glioma who underwent MR spectroscopy and DCE in 3 Tesla MRI machine. The following parameters were used: Ktrans, Ve, Cho/NAA, Cho/Cre. The diagnostic accuracy for glioma grading was determined by ROC analysis.

Results: There were 10 patients in the high-grade group and 5 patients in the low-grade group. Ktrans, Ve, Cho/NAA and Cho/Cre measures differed significantly between high and low-grade tumor. The AUC was 0.956 for Ktrans.

Conclusion: Ktrans, Ve Cho/NAA and Cho/Cre parameters demonstrated to be useful for glioma grading.

Keywords: Spectroscopy, DCE-MRI, glioma grading

TÓM TẮT

Mục tiêu: Đánh giá giá trị của chuỗi xung phổ và chuỗi xung tưới máu trên máy cộng hưởng từ (CHT) 3 Tesla (T) trong chẩn đoán phân bậc u thần kinh đệm (UTKĐ).

Phương pháp: Bệnh nhân được chụp chuỗi xung phổ và tưới máu trên máy 3T với tiêu chuẩn vàng là giải phẫu bệnh. Dùng phần mềm tính toán các giá trị Ktrans, Ve, Cho/NAA, Cho/Cre. Sử dụng đường cong ROC để so sánh các thông số tưới máu và phổ để phân biệt UTK bậc cao và UTKĐ bậc thấp.

Kết quả: Có 15 bệnh nhân UTKĐ, trong đó có 10 bệnh nhân UTKĐ bậc cao, 5 bệnh nhân UTKĐ bậc thấp. Có sự khác biệt có ý nghĩa thống kê (p<0,05) của các thông số tưới máu (Ktrans, Ve) và phổ (Cho/NAA, Cho/Cre) trong phân bậc UTKĐ. Trong đó, Ktrans có giá trị cao nhất để phân bậc u thần kinh đệm (AUC 0,956).

Kết luận: Giá trị Ktrans, Ve của chuỗi xung tưới máu có khả năng phân biệt UTKĐ bậc cao và UTKĐ bậc thấp.

Từ khóa: U thần kinh đệm, cộng hưởng từ phổ, cộng hưởng từ tưới máu